Water Meter Test Benches

Indication Error Test Bench

Product Description

A computer-controlled test and calibration bench that determines the indication error of water meters in line with EN ISO 4064 and OIML R49, designed for type evaluation, initial verification and end-of-line testing. Available with a serial multi-meter line for DN15–DN40 residential and commercial meters and a high-flow line for DN50 and larger meters.

Technical Specifications

Standards
EN ISO 4064, OIML R49
Meter sizes
DN15–DN40 and DN50–DN∞
Reference measurement
Gravimetric (scale) or reference flowmeter
Test points
Q1, Q2, Q3, Q4
Test method
Standing and flying start-stop
Control
PLC + PC software
Reporting
PDF / Excel

Water Meter Test and Calibration BenchFeatures

  • EN ISO 4064 and OIML R49 Compliant

    Test system designed to determine water meter indication errors and for type evaluation and initial verification tests.

  • Gravimetric or Reference Flowmeter Measurement

    Accurate and reliable volume measurement with a precision weighing system or traceable reference flowmeters.

  • DN15–DN40 Water Meters

    Multi-meter test line for residential and commercial mechanical, ultrasonic and electronic water meters.

  • DN50 – DN∞ Large Meters

    High-flow test line for Woltman (turbine), electromagnetic and ultrasonic large-diameter meters.

  • Q1, Q2, Q3 and Q4 Tests

    Automatic indication error analysis at minimum, transitional, permanent and overload flow rates.

  • Automatic PLC Control

    Programmable automatic test sequences with flow, pressure, pump and valve control.

  • Precision Reference Measurement System

    Monitoring of temperature, pressure and flow with high-accuracy reference sensors.

  • Serial Multi-Meter Test Line

    Several water meters are tested simultaneously on the same test line.

  • Optical and Electronic Meter Reading

    Automatic data acquisition via camera, optical sensor, pulse output or communication interfaces.

  • Standing and Flying Start-Stop

    Standing start-stop and diverter-based flying start-stop test methods, as required by the standard.

  • Automatic Indication Error Calculation

    The meter reading is compared with the reference volume and the percentage error is calculated automatically.

  • Pass / Fail Against MPE

    Automatic evaluation against the maximum permissible error of ±5 % in the lower zone and ±2 % in the upper zone (±3 % for water above 30 °C).

  • Flexible PC Software

    Test recipes, flow points, meter data, result records and data management.

  • Automatic Reporting

    Measurement results, error curves and conformity assessments are reported as PDF or Excel.

  • Pneumatic Clamping System

    Pneumatic clamping for fast, leak-tight mounting of meters on the test line.

  • Stable Flow and Pressure

    Stable flow throughout the test with a frequency-controlled pump and constant-head tank options.

  • Air Purging and Leak Check

    Air is purged from the line before the test and a pre-test leak check is carried out under pressure.

  • Barcode / QR Meter Identification

    Meter serial numbers are scanned and matched to the test records for traceability (optional).

  • Low Measurement Uncertainty

    Precise testing with calibrated reference equipment and a traceable measurement infrastructure.